UPS Battery Capacity Calculator

The UPS battery calculator helps you determine the required battery capacity in amp-hours (Ah) and estimated runtime for running home appliances, gas boilers, Wi-Fi routers, and electronics during power outages.

Total Power Load: 200 Вт

Backup Runtime Results

Backup Runtime
4 h 45 m
При постоянной нагрузке 200 Вт и токе разряда 18.9 А
Gross Energy Stored
1200 Вт·год
1.20 кВт·год
Usable Energy
950 Вт·год
DoD 90% × КПД 88%
Discharge Current
18.9 А
12V шина АКБ
Total Power Load
200 Вт
220V змінного струму
Runtime at Different Load Levels:
50 Вт (роутер+ноут)
19h 0m
100 Вт (котел+світло)
9h 30m
200 Вт (котел+ТВ+холод.)
4h 45m
500 Вт (ігровий ПК)
1h 54m
1000 Вт (потужне)
0h 57m

How to use

  1. Select your appliances or input total load consumption in Watts.
  2. Choose battery system voltage (12V, 24V, or 48V).
  3. Set desired backup runtime hours or available battery Ah rating.
  4. Select battery chemistry: lead-acid AGM/GEL or Lithium Iron Phosphate (LiFePO4).
  5. Review recommended battery Ah capacity and runtime calculations.

How UPS Battery Sizing Works

Calculating backup battery capacity uses the formula: Ah = (Watts × Hours) / (Volts × Inverter Efficiency × Depth of Discharge).

  • Inverter efficiency typically ranges between 80% and 90%
  • AGM/GEL batteries should not be discharged past 50–60% DoD to preserve lifespan
  • LiFePO4 lithium batteries safely deliver 90% or more usable depth of discharge

Frequently Asked Questions

How long will a 100Ah battery run appliances?

A 12V 100Ah LiFePO4 battery delivers ~1,100 usable watt-hours, enough to run a 100W load for approximately 11 hours.

Can I use a car battery for a home UPS?

It is not recommended. Car starter batteries release hydrogen fumes indoors and degrade rapidly under deep-cycle power outage conditions.